Oil Testing and Lubricants Analysis for Data Centers

Ensure Data Center Reliability Through Regular Oil Testing

Oil Testing and Lubricants
Analysis for Data Centers

As data centers become more unified and dependent on continuous uptime, monitoring the health of power and cooling systems is essential. Oil Testing and Lubricant Analysis in a preventive maintenance strategy provides early insights into equipment condition, helping prevent failures in generators, UPS systems, chillers, compressors, and pumps. Fluid analysis shifts maintenance from redundancy-based to predictive-based, improving reliability and operational performance.

Atlas Lab offers specialised oil and lubricant testing for data centers, analysing samples as per ASTM, ISO, and IP standards. As a NABL-accredited and ISO 17025-certified laboratory, we evaluate viscosity, oxidation stability, particle count, ferrous density, water content, wear metals, TAN/TBN, and additive depletion. These tests identify contamination, degradation, and early mechanical wear.

With decades of technical expertise and fast reporting, Atlas Lab helps data centers optimise maintenance intervals, reduce downtime, and ensure long-term equipment health. Our solutions provide a cost-effective, data-driven approach to maintaining critical infrastructure.

What are the benefits Oil Testing and Lubricants Analysis for Data Centers?

  • Identifies generator, chiller, pump, and compressor wear before it leads to failure.
  • Ensures critical systems operate smoothly, supporting uninterrupted data center uptime.
  • Transforms maintenance from redundancy-based to performance-driven.
  • Trend analysis helps facility teams forecast issues and plan upgrades effectively.
  • Enables condition-based maintenance instead of fixed intervals, reducing unnecessary servicing.

We test the following Data Center Equipment at our state-of-the-art Lab :

Power Train

  • Back-up generator engine oils
  • Coolants
  • Diesel fuel
  • Transformer oils

Cooling Train

  • HVAC systems
  • Humidifiers
  • Condensers
  • Chillers

The various test conducted at our Testing Lab for Data Centers :

Application / Fluid Recommended Test Slate Sample Size Sample Frequency
Diesel Generators (Lube Oil) Elemental Analysis (21-elements), Viscosity, Fuel Soot, Oxidation, Nitration, Water (%), Glycol, Fuel Dilution, and Total Base Number. 4 oz / 120 mL 250-hrs or Semi-Annual
Diesel Generators (Antifreeze / Coolant) Elemental Analysis (Corrosion & Inhibitor Metals), Appearance, Color, Foam, Odor, pH, Glycol %, Freeze Point, Nitrites, and Total Hardness. 4 oz / 120 mL 250-hrs or Semi-Annual
Turbine Generators (Lube Oil) Elemental Analysis (21-elements), Viscosity, Total Acid Number, Water (ppm) and ISO Particle Count. 4 oz / 120 mL 200-hrs or Quarterly
On-Site Fuel Storage (Diesel Fuel) Particulate Contaminant, Sediment & Water 16 oz / 500 mL Annually
New Fuel Deliveries (Diesel Fuel) Distillation, Density, Cetane Index, Sulfur, Flash Point, Copper Corrosion, Cloud Point, Ash, Sediment & Water, Viscosity, Carbon Residue. 32 oz / 1 L At Delivery
HVAC / CRAC (Refrigeration Oil) Elemental Analysis (21-elements), *Total Acid Number, and Water (ppm),
* Total Base Number
4 oz / 120 mL Semi-Annual
HVAC / CRAC (Refrigerants) Water (ppm), Acidity, Sediment, Appearance, and Color 32 oz. (Steel Canister Required) Semi-Annual
Chillers / Cooling System
(Cooling Water / Condensate)
Elemental Analysis (21-elements), Appearance, pH, Total Hardness, Alkalinity, Total Disolved Solids, Total Suspended Solids, Chloride, Sulphate, Nitrite, Turbidity, Density, Conductivity, % Glycol, Freeze Point 8 oz / 250 mL Semi-Annual
Chillers / Cooling System
(Water-Glycol)
Elemental Analysis (Corrosion & Inhibitor Metals), Appearance, Color, Foam, Odor, pH, Glycol %, Freeze Point, Nitrites, Total Hardness 8 oz / 250 mL Semi-Annual
Transformers (Insulating Oils) Total Acid Number, Color, Visual, Specific Gravity, Moisture Content (Karl Fischer) 16 oz / 500 mL Annual

What is the process of collection of Data Center Samples for Testing?

  • You can directly send your Data Center Oil and Lubricants Sample to us or ask for our Oil and Lubricants Samping Kit.
  • Collect the samples.
  • Courier the samples.
  • On receiving the samples in our laboratory, we will commence testing.
  • Results will be provided in 12 to 24 hours.
  • Technical advice will be provided on testing the samples and assessment of Test Report.

We would be happy to assist you with your testing requirements. Get in touch!